FR (flame retardant\fire resistant) power cable

power cable, 1.Application: FR flame retardant, fire resistant, Standards: IEC ASTM DIN BS JIS CSA AS NFC ASA GOST etc. - more info check here: http://www.sourcingelectricals.com/FR-flame-retardant-fire-resistant-power-cable-11229898/

Quick Brief

Place of Origin: Henan China (Mainland) Brand Name: Yifang Insulation Material: PVC Type: Low Voltage Application: Power Station Conductor Material: Copper or aluminum Jacket: PVC or PE

Product Features:

power cable

1.Application: FR flame retardant, fire resistant

Standards: IEC ASTM DIN BS JIS CSA AS NFC ASA GOST etc.

Business Terms:

Port: Any port in China

Minimum Order Quantity: 500 Meter/Meters

Supply Ability: 50,000 Kilometer/Kilometers per Month

Payment Terms: L/C,T/T

Contact Supplier
FR (flame retardant\fire resistant) power cable
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Drum, Reel, Circle, or according to customers' request

Delivery Detail: according to customers' request, usually 2~4 weeks

Specifications and Product Details:

FR (flame retardant\fire resistan) power cable

Application:
It is used to transmit and distribute power in power transmission and distribution system of 1kV. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Using features:
1. Rated voltage: Uo/U: 0.6/1kV
2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 90º C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250º C.
4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0º C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 2.5Uo+2kV/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.

Standards: IEC, BS, DIN,ASTM, CSA, GOST and so on